Download Lifescan Port Devices Driver



Dec 21, 2020 • Filed to: USB Recovery • Proven solutions

Popular Driver Downloads NI-DAQmx. Provides support for NI data acquisition and signal conditioning devices. Provides support for Ethernet, GPIB, serial, USB. Driver Downloads. Find available Marvell drivers by Platform or Part Number. Driver Downloads. Marvell Drivers.

Have you ever had difficulty connecting your devices to your computer using a Prolific USB to Serial adapter? If yes you are lucky to find this page, it will give you all the information need to fix an unresponsive Serial driver adapter. You may have noticed a yellow exclamation mark hovering over or beside the USB to Serial Driver when searching your Device Manager and if you have we can all agree that it signifies a prevailing problem.

Overview of the Error

If you are not able to connect your device to your PC using a USB to Serial adapter it may be that

  • The USB driver is outdated
  • The USB Driver is missing
  • Or even a corrupted driver

While you can't be so sure what the exact problem is there are solutions you can adopt to fix the issue once and for all. Read on to find quick fixes to resolve the problem.

1# Fix Prolific USB to Serial Driver not Working

Solution: Roll your Prolific USB to Serial Driver back to an older version

Updating your drivers often work wonders for your system because it makes sure that it runs on the latest features that guarantee maximum functionality. Unfortunately updating your drivers can cause this kind of error especially if your latest update does not work too well with your hardware. Once you upgrade your PC to the latest Windows version your Prolific USB to Serial Driver also updates to the latest driver software and if the driver is not compatible with your Hardware issues may arise. To correct the error, you will have to download the driver again by following these steps.

  • Right-click on your PC Start button and open Device Manager
DownloadDownload Lifescan Port Devices Driver
  • Double click LPT and COM ports then locate the Prolific USB to Serial Driver and right-click it so you can select Update Driver
  • For driver software click My computer
  • From My computer select 'Let me pick from a list of drivers available'
  • Choose an older version from the list then click Next
  • The driver you selected will be installed automatically
  • Once it has been downloaded reconnect the driver to see if it works.

2# Fix Prolific USB to Serial Driver 'Coder 10'

Driver issues reveal themselves in so many ways or through messages such as

  • This device will not start (Code 10)
  • There is no driver installed in this device
  • The driver was not successfully installed

A code 10 error may arise because the chip you are using is not an original one. If you are using a fake, the manufacturer has a way of disabling it due to copy write infringement and the copy write takes effect once you download a recent update. To protect your PC from getting this code, you will have to make sure that your Windows 10 never updates a driver without approval. Updates come in the form of 64 bit and 32-bit drivers. Below we will show you how to work your way around the problem.

Window 64 bit Fix

To fix Windows 64 bit OS including Prolific USB to Serial Adapter, follow through these steps.

  • Download 'PL2303_64bit_Installer.exe and Save
  • Remove every USB to Serial adapter from your PC and double click the 'PL2303_64bit_installer.exe
  • Follow the prompt by plugging in one USB to Serial adapter the click on Continue
  • Reboot your PC to get Windows up and running
Download

Download Lifescan Port Devices Driver Windows 10

If you have followed these process through and you still see the same error go to your device manager

  • Open the control panel and navigate to Device Manager
  • From your control panel navigate to the System category and click the Hardware tab
  • Scroll to the LPT/COM port and double click Prolific USB to Serial Comm Port
  • Click Drivers in the Properties section
  • The Driver you choose should read '3.3.2.102 with an appropriate date attached
  • If the date is wrong then it means the wrong driver was installed
  • Unplug the Serial adapter and run the steps again to install the correct driver
Download lifescan port devices driver download

Window 32-bit

For Windows 32-bit OS systems follow these steps

  • You will have to download the 'PL-2303_Driver_Installer.exe and save from Microsoft download link
  • Run the program and eradicate the driver if you can
  • Run the installer once more to install a correct driver

To Troubleshoot for error if your device still does not work

  • Go to Control panel, enter System to access your Device Manager
  • Scroll down to the LPT/ COM port then double click Prolific USB to Serial Comm Port
  • Click Driver in the Windows Properties section
  • The driver must be numbered as '2.0.2.8' and dates accordingly

If the driver was not installed, remove the Serial adapter then run 'PL2303_Driver_Installer.exe' again. Follow directions in Device Manager to download the correct driver

The three solutions listed in this article have proven to be quite helpful in fixing a Prolific USB to Serial driver not working on Windows 10. They may appear confusing at first but if you follow each step in detail you can resolve the issue.

Video Tutorial on How to Fix USB Device Not Recognized

USB Solution

Recover USB Drive
Format USB Drive
Fix/Repair USB Drive
Know USB Drive

Almost all Moates.net products have a USB interface to connect to a computer. (ALDU1, HULOG, Hondalog, BURN1/2, Ostrich 1/2, Roadrunner, Quarterhorse, Jaybird) Fortunately, all Moates.net products with a USB interface use the same USB support chip so they can all use the same drivers. This makes it easy for you – one driver install will take care of ALL Moates products! Check out USB Driver Installation for more on how to reinstall drivers.

The chip in our devices is made by a company called FTDI. This chip is VERY common and is used in everything from USB-serial and USB-parallel adapters sold in computer stores to other automotive electronics products. This is important because of the possibility of a driver conflict between drivers for your Moates.net devices and other devices that also use the FTDI chips. AEM FIC, Hondata S300 and K-Pro and the USB Instruments Stingray and Swordfish (among others) have a tendency to obliterate our drivers and cause driver conflicts. Be warned: the troubleshooting instructions later on this page may cause other devices that use the FTDI chips to stop working. Tip: If you start having driver conflicts, installing the latest drivers from FTDI will often be enough to resolve conflicts and make everything work again.

First step to making sure you don’t have a connection issue is to unplug all USB devices that are not absolutely necessary from your computer.

First, Right click on My Computer. (You might find this on the desktop, you might find this in your start menu. Desktop pictured)

Next, go to the Hardware tab and select “Device Manager.” (note: Windows XP is pictured, but the exact placement of device manager may vary slightly in Win98 and Vista)

Next, go to the “Ports” section of device manager and click the + sign next to it to open it, if it is not already open. You should see something like this:

Now plug in ONE of your Moates.net devices. We are going to plug them in one at a time to figure out which ports Windows is assigning to them. Assuming everything is working, you should see something like this in device manager:

The “USB Serial Port” device pictured is using COM10. Some software has issues with COM ports greater than 8, so the first thing we are going to do is change the port it uses to a port less than 8. Looking at device manager, you can see that Bluetooth Communications Port has used COM5 and a Communications Port has used COM1. We should not use either of these ports. We are going to change to COM3, which is unused. First step: right click on the “USB Serial Port” device and click “Properties.”

Next, click on the “Port Settings” tab at the top of the Window.

Next click the “Advanced” button.

On this screen, there are several things to change. First change the COM Port Number to COM3, the port we decided was open. If all of your ports say “in use” you can still select them, but it is recommended you find an unused port under 8. Second, set the Latency Timer to 1 msec. When you are done, click OK on this screen and the driver screen that follows until you are back at Device Manager.

Download Lifescan Port Devices Driver

These are the optimal settings for our devices (COM1 – COM8 and Latency = 1ms). If you had trouble, try again with these settings. Remember which port your device was using in device manager when it comes time to configure your tuning software.

It is possible to disable devices in Windows. Sometimes this can happen accidentally. If a device is disabled, it has a red X across its icon, like the Bluetooth Communications Port in this picture.

To enable it, right click on the device and select “Enable.” Afterwards, the device should not have a red X across its icon.

Download Lifescan Port Devices Driver Free

Devices can also have issues loading or have device driver problems. When this happens, a yellow exclamation mark appears. Almost 100% of the time, this is a sign that you need to reinstall device drivers. If a simple reinstall does not fix the issue, there is a more heavyhanded method to reinstall drivers using FTCLEAN.